New Surplus 10’ x 10’ Enclosed LNG Command Center – Designed for LNG Stations but Adaptable for Multiple Industrial Gas and Automation Applications


Seller: Gas Equipment For Sale

Manufacturer: BW Systems

Available Quantity: 13

Call: 1 (800) 716-6747

Availability: Available for immediate lease or purchase.


This is a containerized 10x10 enclosed LNG control center originally built for a standalone LNG public fueling station project. It is prewired and based on Allen-Bradley CompactLogix and GuardLogix safety PLC architecture with extensive standard and safety I/O. It is suited for buyers who need a ready control foundation for an LNG station, remote automated site, or an industrial project where safety interlocks and structured I/O capacity matter. Originally designed as an LNG station command center with PLC-based automation and safety controls, but suitable for a wide range of cryogenic, industrial gas, and process control applications.


New Surplus 10x10 Enclosed LNG Control Center (CompactLogix + GuardLogix) New Surplus 10x10 Enclosed LNG Control Center (CompactLogix + GuardLogix) New Surplus 10x10 Enclosed LNG Control Center (CompactLogix + GuardLogix)



See Listing Here.

Equipment Overview and Description

This 10x10 industrial-grade enclosed control center was originally designed for a standalone LNG public station for a major U.S. energy company. It was engineered with redundancy, reliability, and real-world safety applications in mind. Built inside a heavy-duty container, it is prewired and preconfigured with Allen-Bradley CompactLogix and GuardLogix PLC systems and remote-ready communications.


This is not a basic panel. It is a turnkey, customizable industrial control system with extensive I/O options, safety-rated modules, and remote-ready infrastructure. It includes four fully populated PLC racks with a dual PLC setup, including a dedicated Safety PLC (1768-L43S). It is prewired for redundant power, control logic, and safety interlocks.


Data Logging

The PLC time-stamps and logs alarms and operational events. Other events are also recorded as listed in the Data Logging List.



Key Specifications

Enclosure: 10x10 enclosed control center (containerized)

PLC Racks: 4 fully populated PLC racks

PLC Setup: Dual PLC with dedicated Safety PLC (1768-L43S)

Communications: EtherNet/IP and ASCII communications modules included (details below)

Data Logging: Time-stamped alarms and operational event logging capability


Core System Summary

Controllers

1x 1768-L43 CompactLogix Controller (2MB Memory)

1x 1768-L43S Compact GuardLogix Safety Controller


Communication

3x 1768-ENBT EtherNet/IP Modules

1x MVI69E-GSC ProSoft ASCII Communication Module

2x 1734-AENTR Remote I/O Adapters (Dual-Port)


Power

2x 1768-PB3 Power Supplies

Multiple 1734-EP24DC and 1734-FPD I/O Power Distribution


Digital Inputs

48x 1769-IQ16 Standard Digital Inputs (10-30VDC)

32x 1734-IB8S Safety Dual-Channel Inputs


Digital Outputs

16x 1769-OB16 Standard Digital Outputs

48x 1734-OB8S Safety Dual-Channel Outputs


Analog Inputs

24x 1769-IF8 Standard Analog Inputs (Current/Voltage)

32x 1734-IE4S Safety Analog Inputs (Current/Voltage)


Analog Outputs

4x 1769-OF4 Standard Analog Outputs


What’s Included vs Not Included

What’s Included

• Containerized 10x10 enclosed control center

• Four fully populated PLC racks as listed

• CompactLogix (1768-L43) and GuardLogix safety PLC (1768-L43S)

• EtherNet/IP modules, ProSoft ASCII module, remote I/O adapters

• Standard and safety I/O modules and listed power supplies/distribution components

• PLC event time-stamping and alarm/event logging capability (per PLC)


Not Included (unless stated or confirmed)

• Field devices (sensors, transmitters, switches, ESD valves, actuators, motor starters)

• Site wiring, conduit, and termination to field devices

• HMI/SCADA hardware and software licensing

• Networking hardware outside what is listed (switches, radios, firewalls, cellular devices)

• Commissioning services, programming updates, or on-site integration labor

• HVAC, heaters, or environmental conditioning

• UPS or backup power system

[Confirm: whether HVAC, UPS, networking switches, or any operator interface equipment is included.]


Integration and Commissioning Notes

This control center is designed to be integrated into a site control environment. Typical integration steps may include:

• SCADA/HMI point mapping, tag naming alignment, and alarm rationalization

• I/O checkout against your field device list and wiring schedule

• PLC logic review and updates to match your process and shutdown philosophy

• Communications configuration for EtherNet/IP, plus ASCII device integration via the ProSoft module

• FAT planning with defined test scripts (logic, I/O simulation, alarm/event verification)

• SAT planning for field I/O, interlocks, and site communications validation



Compliance and Site Suitability Notes

This unit was originally designed for an LNG public station. Final site suitability depends on your location requirements and how you plan to deploy it.


Condition and Year Clarification

Manufacturer year is listed as 2014 and condition is listed as New. This listing describes these units as new surplus. That typically means inventory that was built for a project and remained unused.



Typical Applications

• LNG station controls foundation for new builds or upgrades

• Remote automated fueling sites and satellite stations

• Safety PLC and interlock control for LNG and industrial operations

• Midstream and downstream automation projects

• Industrial process control where safety I/O and redundancy are required

• SCADA-connected facilities needing a structured controls core


Technical Appendix (Rack and Module Details)

This section is provided for integrators who need part-level detail. It is not required for a high-level purchasing decision, but it helps confirm build content during technical review.



Panel Builders & Integrators: This is not a basic panel. This is a turnkey, customizable industrial control system with extensive I/O options, safety-rated modules, and remote-ready infrastructure. It includes:


 (4) Fully Populated PLC Racks

Dual PLC setup with a dedicated Safety PLC (L43S)

Pre-wired for redundant power, control logic, safety interlocks

Ideal for Panel Build Automation Users, safety-focused industries, and LNG infrastructure


Core System Summary:


Controllers

1x 1768-L43 – CompactLogix Controller (2MB Memory)

1x 1768-L43S – Compact GuardLogix Safety Controller

Communication

3x 1768-ENBT – Ethernet/IP Modules

1x MVI69E-GSC – ProSoft ASCII Communication Module

2x 1734-AENTR – Remote I/O Adapters (Dual-Port)

Power

2x 1768-PB3 – Power Supplies

Multiple 1734-EP24DC & 1734-FPD – I/O Power Distribution

Digital Inputs

48x 1769-IQ16 – 10–30VDC Digital Inputs

32x 1734-IB8S – Safety Dual-Channel Inputs

Digital Outputs

16x 1769-OB16 – Standard Digital Outputs

48x 1734-OB8S – Safety Dual-Channel Outputs

Analog Inputs

24x 1769-IF8 – Standard Analog Inputs (Current/Voltage)

32x 1734-IE4S – Safety Analog Inputs (Current/Voltage)

 Analog Outputs

4x 1769-OF4 – Standard Analog Outputs


Rack-by-Rack PLC Component Details:


Rack 1 – Safety PLC (GuardLogix)


Slot 1 Part # 1768-PB3 CompactLogix L4x DC In Power Supply (120/220VAC - 24VDC)

Slot 2 Part # 1768-ENBT CompactLogix EtherNet/IP Module

Slot 3 Part # 1768-ENBT CompactLogix EtherNet/IP Module

Slot 4 Part # 1768-L43S GuardLogix Safety Controller (2M/0.5M)



Rack 2 – Standard Control PLC


Slot 1 Part # 1768-PB3 Power Supply

Slot 2 Part #  1768-ENBT EtherNet/IP Module

Slot 3 Part # 1768-L43 Controller (2MB)

Slot 4 Part #  MVI69E-GSC ProSoft ASCII Communication Module

Slots 5 through 7 Part #  1769-IF8 3x Analog Input Modules

Slot 8 Part # 1769-OF4 4-Channel Analog Output

Slot 9 through 11 Part # 1769-IQ16 3x Digital Input Modules (10–30VDC)

Slot 12 1769-OB16 Digital Output Module (20.4–26.4VDC)


Rack 3 – Safety Digital I/O


Slot 1 Part # 1734-AENTR – Network Adaptor

Slot 2,4,6,8,10,12,14,16,18, and 20(Even) Part # Alternating 1734-IB8S and 1734-OB8S

 All odd slots: 1734-CTM Terminal Spacers

Slot # 10 & 21:1734-EP24DC and 1734-FPD


Rack 4 – Safety Analog I/O


Slot 1 Part # 1734-AENTR

Slot 2,4,6,8,10,12,14, and 16 Part # 1734-IE4S Safety Analog Input Modules

Odd slots Part # 1734-CTM Terminal Modules

Slot 8 Part # 1734-EP24DC


Component Summary Totals:

Controllers: 1x L43, and 1x L43S Safety Controller

Ethernet/IP: 3 Modules (1768-ENBT)

ASCII Module: 1x MVI69E-GSC

Remote I/O: 2x 1734-AENTR

Digital Inputs: 48x Standard, 32x Safety

Digital Outputs: 16x Standard, 48x Safety

Analog Inputs: 24x Standard, 32x Safety

Analog Outputs: 4x Standard



Pre-Purchase Inspections

Pre-purchase inspections are available during normal business hours by appointment. In-person inspections are welcome.

For buyers traveling by air, complimentary transportation to and from DFW Airport is available for equipment located at the Dallas-area yard. Virtual inspections can also be arranged via FaceTime, Microsoft Teams, or Zoom for domestic and international buyers.

All scheduling is based on U.S. Central Time (CT).


Shipping Arrangements

Shipping assistance is available upon request. The unit is currently located at our yard south of Dallas, Texas. When properly scheduled, loading service can be provided at no additional charge.

[Confirm: loading weight limit and required trailer type.]


Payment Terms

Full payment is required prior to equipment release. Payment is FOB the South Dallas yard.

In-person transactions require a verifiable cashier’s check. For third-party shipping arrangements, a wire transfer must be completed and cleared before release. We prefer to speak directly with buyers to ensure the equipment aligns with project requirements and operational needs.

Please note: used equipment is sold as-is unless otherwise stated.


Flexible Lease or Purchase Options

Terms:

Monthly Rate: Please contact us for a quote

Rates subject to change based on market conditions, availability and timing.


Lease-to-Own / Test-Drive Advantage

This equipment is well suited for projects where long-term site requirements are still being evaluated.

Lease options allow you to:

• Deploy a control center without full capital commitment

• Validate integration and operational fit

• Transition to lease-to-own if it meets long-term needs

• Return the unit when the project concludes


Why Choose Gas Equipment For Sale

Gas Equipment For Sale specializes in cryogenic, LNG, and high-pressure gas storage and transport solutions. Inventory includes LNG tanks, vaporizers, ISO containers, tube trailers, and bulk storage systems.

All equipment is inspected and available from our Texas-based facilities.


Contact Information

Phone: (800) 716-6747

Email: sales@gasequipmentforsale.com

Website: www.gasequipmentforsale.com

Location: Waxahachie, Texas


End of General Terms Template



Industry FAQs


• Q: What is an enclosed LNG control center used for in LNG stations?

A: An enclosed LNG control center houses PLC controls, safety interlocks, power distribution, and communications used to operate and protect LNG fueling stations and other industrial gas processes.


• Q: What does GuardLogix add to an LNG control system compared to a standard CompactLogix PLC?

A: GuardLogix is a safety PLC platform used with safety-rated I/O for shutdown logic and safety interlocks. The CompactLogix controller handles the standard automation and process control logic.


• Q: Can this enclosed LNG control center be used for other industrial automation projects?

A: Yes. While originally designed for an LNG public fueling station, the control architecture and I/O capacity can be adapted for other industrial automation applications requiring safety I/O and structured control systems.


• Q: What does safety dual-channel I/O mean in an LNG control system?

A: Dual-channel safety I/O refers to safety-rated inputs and outputs designed to provide redundancy and fault detection for critical shutdown or protection functions.


• Q: Does this LNG control center include HMI or SCADA software?

A: No HMI panel or SCADA licensing is listed in the available equipment information. Most buyers integrate their own HMI or SCADA platform based on site standards.





Equipment & Listing FAQs


• Q: How many enclosed LNG control centers are available?

A: There are currently 13 units available.


• Q: What size is the enclosed LNG control center container?

A: Each unit is built inside a 10’ × 10’ heavy-duty enclosed control container designed to house automation and safety control systems.


• Q: Which PLC controllers are installed in this LNG control center?

A: The system includes one Allen-Bradley 1768-L43 CompactLogix controller and one 1768-L43S Compact GuardLogix safety controller.


• Q: Does this LNG control system support EtherNet/IP networking and remote I/O?

A: Yes. The system includes three 1768-ENBT EtherNet/IP communication modules and two 1734-AENTR POINT I/O remote adapters for distributed control architecture.


• Q: Why is the equipment year listed as 2014 but the condition listed as new?

A: These units are new surplus, meaning they were manufactured for a project but never installed or placed into service.